Spoon Plate 4.5  |   T-Plate 4.5  |   T-Buttress Plate 4.5  |   L-buttress Plate Right, Left Angled 4.5  |   L-buttress Plate Left, Right Angled 4.5  |   Proximal Lateral Tibial Plate  |   Lateral Tibial Head Buttress Plate 4.5 Left & Right  |   Lateral Tibial Head Buttress Plate LC-DCP 4.5 Left & Right
Spoon Plate 4.5
  • Spoon Plate 4.5. These plates are primarily indicated for pilon fractures that have extensive anterior crushing and provides good posture support.
  • Spoon Plate 4.5s are designed to fit over the anterior crest of the tibia.
  • It should be bent pre-operative to accurately match the anatomy of the segment of bone to be fixed. An oval hole helps in the temporary fixation of the plate before final adjustment and fixation.
  • Holes of the plate allow 4.5 mm cortex screws.
  • Shaft with V-profile for the fixation on the frontal edge of the tibia. Fixation with 4.5mm Cortex screws.

No. of Holes Stainless Steel
5 155.105
6 155.106
No. of Holes TITANIUM
5 Ti-155.105
6 Ti-155.106


T-Plate 4.5
  • T-Plate 4.5 is primarily indicated for the medial tibial plateau. It is also used in the distal tibia, medial distal femur, and proximal humerus fractures.
  • It is designed to use in metaphyseal regions of bone.
  • It is bent to accurately match the anatomy of the segment of bone to be fixed.
  • The long oval hole is provided for temporary fixation of the plate before final adjustment.
  • Holes of the plate allow 4.5 mm cortex screws.
  • Shaft with a round profile, for the humeral and tibial head. Fixation with 4.5 & 6.5mm screws.

No. of Holes Stainless Steel
3 159.103
4 159.104
5 159.105
6 159.106
7 159.107
8 159.108
9 159.109
10 159.110
11 159.111
12 159.112
13 159.113
14 159.114
No. of Holes TITANIUM
3 Ti-159.103
4 Ti-159.104
5 Ti-159.105
6 Ti-159.106
7 Ti-159.107
8 Ti-159.108
9 Ti-159.109
10 Ti-159.110
11 Ti-159.111
12 Ti-159.112
13 Ti-159.113
14 Ti-159.114


T-Buttress Plate 4.5
  • T-Buttress Plate 4.5. These plates are indicated for the lateral plateau fracture of the tibia.
  • It is designed to be used as a buttress plate in areas of thin metaphyseal cortical bone or to prevent the collapsing during the treatment of cancellous defects in that area.
  • Before the surgery, the plate may be bent to accurately match the anatomy of the segment of bone to be fixed.
  • The long oval hole is provided for temporary fixation of the plate before final adjustment and fixation.
  • Holes of the plate allow 4.5 mm cortex screws.
  • With double bend, as a buttress for tibial head fractures. Fixation with 4.5mm & 6.5mm screws.

No. of Holes Stainless Steel
4 160.104
5 160.105
6 160.106
7 160.107
8 160.108
9 160.109
10 160.110
11 160.111
12 160.112
13 160.113
14 160.114
No. of Holes TITANIUM
4 Ti-160.104
5 Ti-160.105
6 Ti-160.106
7 Ti-160.107
8 Ti-160.108
9 Ti-160.109
10 Ti-160.110
11 Ti-160.111
12 Ti-160.112
13 Ti-160.113
14 Ti-160.114


L-buttress Plate Right, Left Angled 4.5
  • With double bend, as a buttress for tibial and humeral head fractures. Left angled for the right leg.

No. of Holes Stainless Steel
3 161.103R
4 161.104R
5 161.105R
6 161.106R
7 161.107R
8 161.108R
9 161.109R
10 161.110R
11 161.111R
12 161.112R
13 161.113R
14 161.114R
No. of Holes TITANIUM
3 Ti-161.103R
4 Ti-161.104R
5 Ti-161.105R
6 Ti-161.106R
7 Ti-161.107R
8 Ti-161.108R
9 Ti-161.109R
10 Ti-161.110R
11 Ti-161.111R
12 Ti-161.112R
13 Ti-161.113R
14 Ti-161.114R

"

L-buttress Plate Left, Right Angled 4.5
  • With double bend, as a buttress for tibial and humeral head fractures. Right-angled for Left leg.

No. of Holes Stainless Steel
3 161.133L
4 161.134L
5 161.135L
6 161.136L
7 161.137L
8 161.138L
9 161.139L
10 161.140L
11 161.141L
12 161.142L
13 161.143L
14 161.144L
No. of Holes TITANIUM
3 Ti-161.133L
4 Ti-161.134L
5 Ti-161.135L
6 Ti-161.136L
7 Ti-161.137L
8 Ti-161.138L
9 Ti-161.139L
10 Ti-161.140L
11 Ti-161.141L
12 Ti-161.142L
13 Ti-161.143L
14 Ti-161.144L


Proximal Lateral Tibial Plate
  • Proximal Lateral Tibial Plate. These plates are indicated for metaphyseal, extra, and intraarticular fractures of the proximal tibia.
  • An anatomically designed plate fits over the proximal tibia from the lateral side.
  • These plates are designed separately for both right and left tibia and are available in a variety of lengths.
  • All holes of the plate allow 4.5 mm cortical screws.

No. of Holes STAINLESS STEEL
Left Right
3 622.003L 622.003R
5 622.005L 622.005R
7 622.007L 622.007R
9 622.009L 622.009R
11 622.011L 622.011R
13 622.013L 622.013R
No. of Holes TITANIUM
Left Right
3 Ti-622.003L Ti-622.003R
5 Ti-622.005L Ti-622.005R
7 Ti-622.007L Ti-622.007R
9 Ti-622.009L Ti-622.009R
11 Ti-622.011L Ti-622.011R
13 Ti-622.013L Ti-622.013R


Lateral Tibial Head Buttress Plate 4.5 Left & Right
  • Lateral Tibial Head Buttress Plate 4.5. These plates are indicated for treating shaft fractures, metaphyseal fractures, intra-articular and periprosthetic fractures of the proximal tibia.
  • An anatomically designed plate fits over the proximal tibia from the lateral side.
  • These plates are designed separately for both right and left tibia and are available in a variety of lengths.
  • All holes of the plate allow 4.5 mm cortical screws.
  • With double bend, as a buttress for tibial and humeral head fractures. Left angled for the right leg.

No. of Holes STAINLESS STEEL
Left Right
5 165.105L 165.005R
7 165.107L 165.007R
9 165.109L 165.009R
11 165.111L 165.011R
13 165.113L 165.013R
No. of Holes TITANIUM
Left Right
5 Ti-165.105L Ti-165.005R
7 Ti-165.107L Ti-165.007R
9 Ti-165.109L Ti-165.009R
11 Ti-165.111L Ti-165.011R
13 Ti-165.113L Ti-165.013R


Lateral Tibial Head Buttress Plate LC-DCP 4.5 Left & Right
  • Lateral Tibial Head Buttress Plate 4.5. These plates are indicated for treating shaft fractures, metaphyseal fractures, intra-articular and periprosthetic fractures of the proximal tibia.
  • An anatomically designed plate fits over the proximal tibia from the lateral side.
  • These plates are designed separately for both right and left tibia and are available in a variety of lengths.
  • Low Contact plate design reduces the plate and bone contact, this feature reduces vascular trauma.
  • All holes of the plate allow 4.5 mm cortical screws.

No. of Holes STAINLESS STEEL
Left Right
5 165.305L 165.405R
7 165.307L 165.407R
9 165.309L 165.409R
11 165.311L 165.411R
13 165.313L 165.413R
No. of Holes TITANIUM
Left Right
5 Ti-165.305L Ti-165.405R
7 Ti-165.307L Ti-165.407R
9 Ti-165.309L Ti-165.409R
11 Ti-165.311L Ti-165.411R
13 Ti-165.313L Ti-165.413R