Straight Plate 2.0  |   L Plate 2.0  |   T Plate 2.0  |   DCP Plate 2.0  |   Condylar Plate
Straight Plate 2.0
  • Mini Straight Plates for 2mm Screws is used for i) Diaphysis Noncomminuted ii) Diaphysis wedge Comminuted iii) Diaphysis Comminuted fracture of both Hand and Foot Phalanges.
  • All holes of the plate support 1.5 and 2.0 mm cortical screws.
No. of Holes Stainless Steel
2 121.102
3 121.103
4 121.104
5 121.105
6 121.106
7 121.107
8 121.108
No. of Holes Titanium
2 Ti-121.102
3 Ti-121.103
4 Ti-121.104
5 Ti-121.105
6 Ti-121.106
7 Ti-121.107
8 Ti-121.108

L Plate 2.0
  • L Plate 2.0 is used for i) Proximal and Distal Extra-articular ii) Proximal and Distal partial Articular iii) Proximal and Distal complete Articular fractures of both Hand and Foot Phalanges.
  • All holes of plate support 1.5 and 2.0 mm Cortical screw.
No. of Holes Left / Right Right Angle Oblique Angle
2 Left 122.101 122.103
2 Right 122.102 122.104
3 Left 122.105 122.107
3 Right 122.106 122.108
4 Left 122.109 122.111
4 Right 122.110 122.112
5 Left 122.113 122.115
5 Right 122.114 122.116
No. of Holes Left / Right Right Angle Oblique Angle
2 Left TI-122.101 TI-122.103
2 Right TI-122.102 TI-122.104
3 Left TI-122.105 TI-122.107
3 Right TI-122.106 TI-122.108
4 Left TI-122.109 TI-122.111
4 Right TI-122.110 TI-122.112
5 Left TI-122.113 TI-122.115
5 Right TI-122.114 TI-122.116

T Plate 2.0
T Plate 2.0

Zoom

  • Mini T Plate for 2mm Screw is used for i) Proximal and Distal Extra-articular ii) Proximal and Distal partial Articular iii) Proximal and Distal complete Articular fractures of both Hand and Foot Phalanges.
  • All holes of the plate support 1.5 and 2.0 mm Cortical screw.
No. of Holes Code
2 123.100
3 123.103
4 123.104
5 123.105
No. of Holes Code
2 Ti-123.100
3 Ti-123.103
4 Ti-123.104
5 Ti-123.105

Dynamic Compression Plate 2.0
  • Dynamic Compression Plate 2.0mm is used for Diaphyseal Noncomminuted (Spiral, Oblique or Transverse) and Diaphysis Wedge ( Spiral or Bending) fractures of both Hand and Foot Phalanges.
  • All holes of plate support 1.5 and 2.0 mm Cortical Screws.
No. of Holes Stainless Steel
4 121.554
5 121.555
6 121.556
7 121.557
8 121.558
No. of Holes Titanium
4 Ti-121.554
5 Ti-121.555
6 Ti-121.556
7 Ti-121.557
8 Ti-121.558

Condylar Plate
  • Condylar Plate is used for Proximal Partial Articular (Unicondyle Medial or Unicondyle Lateral) and Distal Partial Articular (Unicondyle Medial or Unicondyle Lateral) fracture of both Hand and Foot Phalanges.
  • All holes of plate support 1.5/2.0 and 2.7mm Cortical screws.
Screw Ø mm Type Length in mm Stainless Steel
1.5 Pin Left 36 74.01
1.5 Pin Right 36 74.02
2.0 Pin Left 39 74.03
2.0 Pin Right 39 74.04
2.7 Pin Left 57 74.05
2.7 Pin Right 57 74.06
Screw Ø mm Type Length in mm Titanium
1.5 Pin Left 36 Ti-74.01
1.5 Pin Right 36 Ti-74.02
2.0 Pin Left 39 Ti-74.03
2.0 Pin Right 39 Ti-74.04
2.7 Pin Left 57 Ti-74.05
2.7 Pin Right 57 Ti-74.06