T Plate 2.7  |   DCP Plate 2.7  |   Quarter Tubular Plate  |   Condylar Plate  |   Straight Reconstruction Plate 2.7  |   L Plate 2.7
T Plate 2.7
  • T Plate 2.7 is used for Proximal Extra-articular (Comminuted or Noncomminuted), Distal Extra-articular (Comminuted or Noncomminuted), Proximal and Distal Partial Articular, Proximal Articular (Comminuted or Noncomminuted) and, Distal Articular (Metaphyseal and Comminuted Metaphyseal) fractures of Metacarpals and Metatarsals.
  • All holes of the plate support 2.7 mm Cortical Screws.
No. of Holes Code
2 134.099
3 134.100
4 134.104
5 134.105
No. of Holes Code
2 Ti-134.099
3 Ti-134.100
4 Ti-134.104
5 Ti-134.105

Dynamic Compression Plate 2.7
  • Dynamic Compression Plate 2.7 is used for Diaphysis Noncomminuted (Spiral, Oblique or Transverse) and Diaphysis Wedge (Spiral, Bending or Comminuted) fractures of Metacarpals and Metatarsals.
  • All holes of the plate support 2.7 mm cortical screws.
  • Thickness
    • (upto 6 Holes): 2mm
    • (7 to 12 Holes): 2.5mm
No. of Holes Code
2 132.102
3 132.103
4 132.104
5 132.105
6 132.106
7 132.107
8 132.108
9 132.109
10 132.110
12 132.112
No. of Holes Code
2 Ti-132.102
3 Ti-132.103
4 Ti-132.104
5 Ti-132.105
6 Ti-132.106
7 Ti-132.107
8 Ti-132.108
9 Ti-132.109
10 Ti-132.110
12 Ti-132.112

Quarter Tubular Plate 2.7
  • Quarter Tubular Plate 2.7 is used for Diaphysis Noncomminuted (Spiral, Oblique or Transverse), Diaphysis Wedge (Spiral, Bending or Comminuted) and Diaphysis Comminuted (Segmental or Complex comminuted) fractures of Metacarpals and Metatarsals.
  • All holes of the plate support 2.7 mm Cortical screws.
No. of Holes Code
3 131.103
4 131.104
5 131.105
6 131.106
7 131.107
8 131.108
No. of Holes Code
3 Ti-131.103
4 Ti-131.104
5 Ti-131.105
6 Ti-131.106
7 Ti-131.107
8 Ti-131.108

Condylar Plate
  • Condylar Plate is used for Proximal Partial Articular (Unicondyle Medial or Unicondyle Lateral) and Distal Partial Articular (Unicondyle Medial or Unicondyle Lateral) fracture of both Hand and Foot Phalanges.
  • All holes of plate support 1.5/2.0 and 2.7mm Cortical screws.
Screw Ø mm Type Length in mm Stainless Steel
1.5 Pin Left 36 74.01
1.5 Pin Right 36 74.02
2.0 Pin Left 39 74.03
2.0 Pin Right 39 74.04
2.7 Pin Left 57 74.05
2.7 Pin Right 57 74.06
Screw Ø mm Type Length in mm Titanium
1.5 Pin Left 36 Ti-74.01
1.5 Pin Right 36 Ti-74.02
2.0 Pin Left 39 Ti-74.03
2.0 Pin Right 39 Ti-74.04
2.7 Pin Left 57 Ti-74.05
2.7 Pin Right 57 Ti-74.06


Reconstruction Plate 2.7 Straight
  • Reconstruction Plate 2.7 Straight is used to fix Diaphysis Noncomminuted (Spiral, Oblique or Transverse) and Diaphysis Wedge (Spiral, Bending or Comminuted) fractures of metacarpals and metatarsals.
  • All holes of the plate supports 2.7 mm Cortical screws.
  • Specially designed plate can be easily bend as required.
No. of Holes Code
2 135.102
4 135.104
6 135.106
8 135.108
10 135.110
12 135.112
14 135.114
16 135.116
18 135.118
20 135.120
22 135.122
24 135.124
No. of Holes Code
2 Ti-135.102
4 Ti-135.104
6 Ti-135.106
8 Ti-135.108
10 Ti-135.110
12 Ti-135.112
14 Ti-135.114
16 Ti-135.116
18 Ti-135.118
20 Ti-135.120
22 Ti-135.122
24 Ti-135.124

L Plate 2.7
  • L Plate 2.7 is used for i) Proximal and Distal Extra-articular ii) Proximal and Distal partial Articular iii) Proximal and Distal complete Articular fractures of Metacarpals and Metatarsals.
  • All holes of the plate support 2.7 mm Cortical screw.
No. of Holes Left / Right Right Angle Oblique Angle
2 Left 133.097 133.099
2 Right 133.098 133.100
3 Left 133.101 133.103
3 Right 133.102 133.104
4 Left 133.105 133.107
4 Right 133.106 133.108
5 Left 133.109 133.111
5 Right 133.110 133.112
No. of Holes Left / Right Right Angle Oblique Angle
2 Left TI-133.097 TI-133.099
2 Right TI-133.098 TI-133.100
3 Left TI-133.101 TI-133.103
3 Right TI-133.102 TI-133.104
4 Left TI-133.105 TI-133.107
4 Right TI-133.106 TI-133.108
5 Left TI-133.109 TI-133.111
5 Right TI-133.110 TI-133.112