Column  |   Extra Long  |   Extra-articular  |   Extra Articular (5 Head Holes)  |   Juxta Articular  |   Juxta Articular Buttress  |   Safety Lock Screw Ø 2.4mm - Self Tapping  |   Safety Lock Screw Ø 2.7mm - Self Tapping  |   Safety Lock Screw Ø 3.5mm - Self Tapping  |   Safety Lock Screw Ø 3.5mm Self Tapping and Self Drilling  |   Cortex Screw Ø 3.5mm, Self Tapping  |   Small Fragment Safety Lock Instruments Set  |   Small Fragment Instrument Set Combo With Standard Instruments & Locking Instruments.
Volar Column Distal Radius Safety Lock Plate 2.4 (8 Head Holes)
Indications:

Volar Column Distal Radius Safety Lock Plate 2.4 (8 Head Holes) is indicated for the fixation of intra- and extra-articular fractures and osteotomies of the distal radius. Multiple distal locking screw options offer a fixed-angle construct to support the articular surface, reduce the need for bone graft and obtain fixation in osteoporotic bone.

Plate Features:
  • Anatomically contoured Volar Column Distal Radius Safety Lock Plate 2.4.
  • Multiple locking screw options in the plate head assist in the fixation of the radial and intermediate column.
  • Locking plates provides anatomical reduction. It means the adaptation of fracture fragments to restore normal anatomy.
  • fixation stability: It gives stability in fixation as required by the nature of the fracture. Plate provides optimal compression and stability.
  • Plate preserves blood supply to soft tissues and bone.
L/R No. of Holes Stainless Steel
Left 3 SF-120.803L
Right 3 SF-120.803R
Left 4 SF-120.804L
Right 4 SF-120.804R
Left 5 SF-120.805L
Right 5 SF-120.805R
L/R No. of Holes Titanium
Left 3 Ti-SF-120.803L
Right 3 Ti-SF-120.803R
Left 4 Ti-SF-120.804L
Right 4 Ti-SF-120.804R
Left 5 Ti-SF-120.805L
Right 5 Ti-SF-120.805R

Volar Column Distal Radius Safety Lock Plate 2.4 (9 Head Holes)
Indications:

Volar Column Distal Radius Safety Lock Plate 2.4 (9 Head Holes) is indicated for the fixation of intra- and extra-articular fractures and osteotomies of the distal radius. Multiple distal locking screw options offer a fixed-angle construct to support the articular surface, reduce the need for bone graft and obtain fixation in osteoporotic bone.

Plate Features:
  • Anatomically contoured Volar Column Distal Radius Safety Lock Plate 2.4.
  • Multiple locking screw options in the plate head assist in the fixation of the radial and intermediate column.
  • Locking plates provides anatomical reduction. It means the adaptation of fracture fragments to restore normal anatomy.
  • fixation stability: It gives stability in fixation as required by the nature of the fracture. Plate provides optimal compression and stability.
  • Plate preserves blood supply to soft tissues and bone.
L/R No. of Holes Stainless Steel
Left 3 SF-120.903L
Right 3 SF-120.903R
Left 4 SF-120.904L
Right 4 SF-120.904R
Left 5 SF-120.905L
Right 5 SF-120.905R
L/R No. of Holes Titanium
Left 3 Ti-SF-120.903L
Right 3 Ti-SF-120.903R
Left 4 Ti-SF-120.904L
Right 4 Ti-SF-120.904R
Left 5 Ti-SF-120.905L
Right 5 Ti-SF-120.905R

Volar Distal Radius Safety Lock Plate 2.4, Extra-Articular, Extra-long
Indications:

Volar Distal Radius Safety Lock Plate 2.4, Extra-Articular, Extra-long is indicated for treating distal radius fractures with extension into the shaft.

Plate Features:
  • Anatomically contoured Volar Distal Radius Safety Lock Plate 2.4, Extra-Articular, Extra-long.
  • Locking plates provides anatomical reduction. It means the adaptation of fracture fragments to restore normal anatomy.
  • fixation stability: It gives stability in fixation as required by the nature of the fracture. Plate provides optimal compression and stability.
  • Plate preserves blood supply to soft tissues and bone.
Head Holes Shaft Holes Stainless Steel
4 8 SF-122.108
4 10 SF-122.110
4 12 SF-122.112
Head Holes Shaft Holes Titanium
4 8 Ti-SF-122.108
4 10 Ti-SF-122.110
4 12 Ti-SF-122.112

Volar Distal Radius Safety Lock Plate 2.4, Extra Articular (5 Head Holes)
Indications:

Volar Distal Radius Safety Lock Plate 2.4, Extra Articular (5 Head Holes) is indicated for displaced extra-articular and intra-articular distal radius fractures and corrective osteotomies of the distal radius.

Plate Features:
  • Anatomically contoured Volar Distal Radius Safety Lock Plate 2.4, Extra Articular (5 Head Holes)
  • Locking plates provides anatomical reduction. It means the adaptation of fracture fragments to restore normal anatomy.
  • fixation stability: It gives stability in fixation as required by the nature of the fracture. Plate provides optimal compression and stability.
  • Plate preserves blood supply to soft tissues and bone.
L/R No. of Holes Stainless Steel
Left 3 SF-121.504L
Right 3 SF-121.504R
Left 5 SF-121.505L
Right 5 SF-121.505R
L/R No. of Holes Titanium
Left 3 Ti-SF-121.504L
Right 3 Ti-SF-121.504R
Left 5 Ti-SF-121.505L
Right 5 Ti-SF-121.505R

Volar Distal Radius Safety Lock Plate 2.4, Extra Articular (4 Head Holes)
Indications:

Volar Distal Radius Safety Lock Plate 2.4, Extra Articular (4 Head Holes) is indicated for displaced extra-articular and intra-articular distal radius fractures and corrective osteotomies of the distal radius.

Plate Features:
  • Anatomically contoured Volar Distal Radius Safety Lock Plate 2.4, Extra Articular (4 Head Holes)
  • Locking plates provides anatomical reduction. It means the adaptation of fracture fragments to restore normal anatomy.
  • fixation stability: It gives stability in fixation as required by the nature of the fracture. Plate provides optimal compression and stability.
  • Plate preserves blood supply to soft tissues and bone.
L/R No. of Holes Stainless Steel
Left 3 SF-121.304L
Right 3 SF-121.304R
Left 5 SF-121.305L
Right 5 SF-121.305R
L/R No. of Holes Titanium
Left 3 Ti-SF-121.304L
Right 3 Ti-SF-121.304R
Left 5 Ti-SF-121.305L
Right 5 Ti-SF-121.305R

Volar Distal Radius Safety Lock Plate 2.4, Juxta-Articular (5 Head Holes)
Indications:

Volar Distal Radius Safety Lock Plate 2.4, juxta-articular (5 Head Holes) is indicated for displaced extra-articular and intra-articular distal radius fractures and corrective osteotomies of the distal radius.

Plate Features:
  • Anatomically contoured Volar Distal Radius Safety Lock Plate 2.4, juxta-articular (5 Head Holes)
  • Locking plates provides anatomical reduction. It means the adaptation of fracture fragments to restore normal anatomy.
  • fixation stability: It gives stability in fixation as required by the nature of the fracture. Plate provides optimal compression and stability.
  • Plate preserves blood supply to soft tissues and bone.
L/R No. of Holes Stainless Steel
Left 3 SF-123.503L
Right 3 SF-123.503R
Left 5 SF-123.505L
Right 5 SF-123.505R
L/R No. of Holes Titanium
Left 3 Ti-SF-123.503L
Right 3 Ti-SF-123.503R
Left 5 Ti-SF-123.505L
Right 5 Ti-SF-123.505R

Volar Distal Radius Buttress Safety Lock Plate 2.4, Juxta-Articular (5 Head Holes)
Indications:

Volar Distal Radius Safety Lock Plate 2.4, juxta-articular (5 Head Holes) is indicated for displaced extra-articular and intra-articular distal radius fractures and corrective osteotomies of the distal radius.

Plate Features:
  • Anatomically contoured Volar Distal Radius Safety Lock Plate 2.4, juxta-articular (5 Head Holes)
  • Locking plates provides anatomical reduction. It means the adaptation of fracture fragments to restore normal anatomy.
  • fixation stability: It gives stability in fixation as required by the nature of the fracture. Plate provides optimal compression and stability.
  • Plate preserves blood supply to soft tissues and bone.
L/R No. of Holes Stainless Steel
Left 3 SF-124.503L
Right 3 SF-124.503R
L/R No. of Holes Titanium
Left 3 Ti-SF-124.503L
Right 3 Ti-SF-124.503R

Safety Lock Screw Ø 2.4mm - Self Tapping
  • Drill Bit: 1.8mm
Length in mm Codes
Stainless Steel Titanium
6 SF-100.206 Ti-SF-100.206
8 SF-100.208 Ti-SF-100.208
10 SF-100.210 Ti-SF-100.210
12 SF-100.212 Ti-SF-100.212
14 SF-100.214 Ti-SF-100.214
16 SF-100.216 Ti-SF-100.216
18 SF-100.218 Ti-SF-100.218
20 SF-100.220 Ti-SF-100.220
22 SF-100.222 Ti-SF-100.222
24 SF-100.224 Ti-SF-100.224
26 SF-100.226 Ti-SF-100.226
28 SF-100.228 Ti-SF-100.228
30 SF-100.230 Ti-SF-100.230

Safety Lock Screw Ø 2.7mm - Self Tapping
  • Safety Lock Screw Ø 2.7mm - Self Tapping is used for the Fixation of a Small Fragment Safety Lock Plate.
  • The larger core dia of the screw provides strength and a threaded head for locking in the plate.
  • The self-tapping feature eliminates the use of the bone tap.
  • Drill Bit: 2.0mm
Length in mm Codes
Stainless Steel Titanium
20 SF-101.420 Ti-SF-101.420
22 SF-101.422 Ti-SF-101.422
24 SF-101.424 Ti-SF-101.424
26 SF-101.426 Ti-SF-101.426
28 SF-101.428 Ti-SF-101.428
30 SF-101.430 Ti-SF-101.430
32 SF-101.432 Ti-SF-101.432
34 SF-101.434 Ti-SF-101.434
36 SF-101.436 Ti-SF-101.436
38 SF-101.438 Ti-SF-101.438
40 SF-101.440 Ti-SF-101.440
42 SF-101.442 Ti-SF-101.442
44 SF-101.444 Ti-SF-101.444
46 SF-101.446 Ti-SF-101.446
48 SF-101.448 Ti-SF-101.448
50 SF-101.450 Ti-SF-101.450
52 SF-101.452 Ti-SF-101.452
54 SF-101.454 Ti-SF-101.454
56 SF-101.456 Ti-SF-101.456
58 SF-101.458 Ti-SF-101.458
60 SF-101.460 Ti-SF-101.460


Safety Lock Screw Ø 3.5mm - Self Tapping
  • Safety Lock Screw Ø 3.5mm- Self Tapping is used for the fixation of Small Fragment Safety Lock Plate.
  • The larger core dia of the screw provides strength and a threaded head for locking in the plate.
  • Self-tapping eliminates the use of the bone tap.
  • Drill Bit: 2.8mm
Length in mm Codes
Stainless Steel Titanium
10 SF-102.210 Ti-SF-102.210
12 SF-102.212 Ti-SF-102.212
14 SF-102.214 Ti-SF-102.214
16 SF-102.216 Ti-SF-102.216
18 SF-102.218 Ti-SF-102.218
20 SF-102.220 Ti-SF-102.220
22 SF-102.222 Ti-SF-102.222
24 SF-102.224 Ti-SF-102.224
26 SF-102.226 Ti-SF-102.226
28 SF-102.228 Ti-SF-102.228
30 SF-102.230 Ti-SF-102.230
32 SF-102.232 Ti-SF-102.232
34 SF-102.234 Ti-SF-102.234
36 SF-102.236 Ti-SF-102.236
38 SF-102.238 Ti-SF-102.238
40 SF-102.240 Ti-SF-102.240
42 SF-102.242 Ti-SF-102.242
44 SF-102.244 Ti-SF-102.244
46 SF-102.246 Ti-SF-102.246
48 SF-102.248 Ti-SF-102.248
50 SF-102.250 Ti-SF-102.250
52 SF-102.252 Ti-SF-102.252
54 SF-102.254 Ti-SF-102.254
56 SF-102.256 Ti-SF-102.256
58 SF-102.258 Ti-SF-102.258
60 SF-102.260 Ti-SF-102.260


Safety Lock Screw Ø 3.5mm Self Tapping and Self Drilling
  • Drill Bit: 2.8mm
Length in mm Codes
Stainless Steel Titanium
10 SF-102.410 Ti-SF-102.410
12 SF-102.412 Ti-SF-102.412
14 SF-102.414 Ti-SF-102.414
16 SF-102.416 Ti-SF-102.416
18 SF-102.418 Ti-SF-102.418
20 SF-102.420 Ti-SF-102.420
22 SF-102.422 Ti-SF-102.422
24 SF-102.424 Ti-SF-102.424
26 SF-102.426 Ti-SF-102.426
28 SF-102.428 Ti-SF-102.428
30 SF-102.430 Ti-SF-102.430
32 SF-102.432 Ti-SF-102.432
34 SF-102.434 Ti-SF-102.434
36 SF-102.436 Ti-SF-102.436
38 SF-102.438 Ti-SF-102.438
40 SF-102.440 Ti-SF-102.440
42 SF-102.442 Ti-SF-102.442
44 SF-102.444 Ti-SF-102.444
46 SF-102.446 Ti-SF-102.446
48 SF-102.448 Ti-SF-102.448
50 SF-102.450 Ti-SF-102.450
52 SF-102.452 Ti-SF-102.452
54 SF-102.454 Ti-SF-102.454
56 SF-102.456 Ti-SF-102.456
58 SF-102.458 Ti-SF-102.458
60 SF-102.460 Ti-SF-102.460

Cortex Screw Ø 3.5mm, Self Tapping
  • Cortex Screw Ø 3.5mm is used for the fixation of small fragment implants.
  • A larger Core of the screw provides strength and a spherical surface under the head of the screw is for better compression.
  • The self-tapping feature eliminates the use of the bone tap.
  • Use 2.5mm Drill Bit.
Length in mm Codes
Stainless Steel Titanium
10 102.210 Ti-102.210
12 102.212 Ti-102.212
14 102.214 Ti-102.214
16 102.216 Ti-102.216
18 102.218 Ti-102.218
20 102.220 Ti-102.220
22 102.222 Ti-102.222
24 102.224 Ti-102.224
26 102.226 Ti-102.226
28 102.228 Ti-102.228
30 102.230 Ti-102.230
32 102.232 Ti-102.232
34 102.234 Ti-102.234
36 102.236 Ti-102.236
38 102.238 Ti-102.238
40 102.240 Ti-102.240
42 102.242 Ti-102.242
44 102.244 Ti-102.244
46 102.246 Ti-102.246
48 102.248 Ti-102.248
50 102.250 Ti-102.250

Small Fragment Safety Lock Instruments Set
AS432 Small Fragment Safety Lock Instruments Set
Set Consisting of : Units
AS432.001 - Drill Bit Ø 2.8mm, Length 165mm, Calibrated, 2-flute, for Quick Coupling 2
AS432.005 - 2.8mm Drill Sleeve for 3.5mm Safety Lock Screws 2
AS432.009 - Torque Limiting Screw Driver, 2.5mm Tip 1
AS432.013 - T-Handle for Quick Coupling 1
AS432.017 - HSS Drill Bit Ø 2.5mm (Blue Coating) 2
AS432.021 - Extraction Screw (Left Hand Thread), Conical, for Screws Ø 3.5mm 1
AS432.025 - Centering Sleeve for Kirschner Wire Ø 1.2mm, Length 85mm 1
432.000 - Empty Container  
Optional Instruments (To be Ordered Separately)  
AS432.030 - Torque Limiting Screw Driver, 1.5mm Tip. 1
AS432.031 - Drill Bit Ø 2.0mm, Length 150mm, 2-flute for Quick Coupling 1
AS432.035 - 2.0mm Drill Sleeve for 2.4/2.7mm Safety Locking Screws 1

Small Fragment Instrument Set Combo With Standard Instruments & Locking Instruments.
AS140 Small Fragment Instrument Set Combo With Standard Instruments & Locking Instruments.
Set Consisting of : Units
Standard Instruments  
260.250 - Drill Bit 2.5mm Dia 2
260.350 - Drill Bit 3.5mm Dia 2
305.020 - Counter Sink for 3.5, 4.0mm Screws (6.0mm Head) 1
264.025 - Tap of 3.5mm Cortex Screw 2
264.038 - Tap of 4.0mm Cancellous Screw 2
306.010 - Quick Coupling Handle (T-Type) 1
307.060 - Drill & Tap Sleeve Combined 3.5/2.5mm 1
307.090 - Insert Drill Sleeve 2.5mm / 3.5mm 1
301.060 - Small Hexagonal Screw Driver Shaft 1
301.040 - Small Hexagonal Screw Driver 1
303.010 - Depth Gauge Small 1
302.010 - Small Plate Bender for Plates 2.7 & 3.5mm 1
340.020 - Self Centering Bone Holding Forceps- 190mm 1
379.015 - Hohman Retractors, Small, 8mm Wide, 160mm 2
381.012 - Periosteal Elevator, Straight/Curved 12mm 1
379.020 - Hohman Retractors, 15mm Wide, 160mm 2
341.025 - Reduction Forceps, Serrated - 140mm 1
342.035 - Reduction Forceps, Pointed - 140mm 1
304.010 - Neutral and Loaded Drill Guide (Small) 1
Locking Instruments  
AS432.001 - Drill Bit Ø 2.8mm, Length 165mm, Calibrated, 2-flute, for Quick Coupling 2
AS432.005 - 2.8mm Drill Sleeve for 3.5mm Safety Lock Screws 2
AS432.009 - Torque limiting Screw Driver, 2.5mm Tip 1
AS432.021 - Extraction Screw (Left Hand Thread), Conical, for Screws Ø 3.5mm 1
AS432.025 - Centering Sleeve for Kirschner Wire Ø 1.2mm, Length 85mm 1
AS140.000 - Empty Container  
Optional Instruments (To be Ordered Separately)  
AS432.030 - Torque Limiting Screw Driver, 1.5mm Tip. 1
AS432.031 - Drill Bit Ø 2.0mm, Length 150mm, 2-flute for Quick Coupling 1
AS432.035 - 2.0mm Drill Sleeve for 2.4/2.7mm Safety Locking Screws 1
>